Back to Top

Hi, Guest!

Clamp Meters 2660 CL AC/ DC Clamp Meters

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Rantai
Dilihat Sebanyak
:
6 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Clamp Meters 2660 CL AC/ DC Clamp Meters

FEATURES Ï 4000 counts. Ï Voltage measurement, current measurement, resistor measurement, frequency counter, capacitor measurement. Ï Bargraph indication. Ï Range change function. Ï Data hold function freezes the reading. Ï REL function. Ï Peak function. Ï VAHz mode measures frequency in ACV and ACA mode. Ï Diode measurement. Ï Max. / Min. function. Ï Continuity check. Ï Low battery indication. Ï Auto Power Off ( APO) function. Ï Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals. SPECIFICATIONS DC Voltage : Ranges : 400mV / 4V / 40V / 400V / 600V Resolution : 0.1mV / 1mV / 10mV / 100mV / 1V Accuracy : ± ( 1.0% rdg+ 3dgt) Overload protection : 650V DC AC Voltage : Ranges : 400mV / 4V / 40V / 400V / 600V Resolution : 0.1mV / 1mV / 10mV / 100mV / 1V Accuracy : 400mV : ± ( 2.0% rdg+ 3dgt) 4V~ 600V : ± ( 1.5% rdg+ 3dgt) Overload protection : 650V DC rms Frequency Response : 0~ 400mV at 40Hz~ 120Hz 4V~ 600V at 40Hz~ 500Hz AC Current : Ranges : 400A / 600A Resolution : 0.1A / 1A Accuracy : ± ( 1.5% rdg+ 4dgt) / ± ( 2.0% rdg+ 4dgt) Frequency Response : 40Hz~ 500Hz DC Current : Ranges : 400A / 600A Resolution : 0.1A / 1A Accuracy : ± ( 1.5% rdg+ 4dgt) / ± ( 2.0% rdg+ 4dgt) Resistance: Ranges : 400© / 4k© / 40k© / 400k© / 4M© / 40M© Resolution : 0.1© / 1© / 10© / 100© / 1k© / 10k© Accuracy : 400© ~ 4M© : ± ( 1.5% rdg+ 3dgt) 40M© : ± ( 2.0% rdg+ 4dgt) Continuity: Ranges : 400© Audible threshold : Less than 35© Fequence: Ranges : 4kHz / 40kHz / 400kHz / 4MHz / 40MHz Resolution : 1Hz / 10Hz / 100Hz / 1kHz / 10kHz Accuracy : 4kHz~ 400kHz : ± ( 0.3% rdg+ 2dgt) 4MHz : ± ( 0.4% rdg+ 2dgt) 40MHz : ± ( 0.5% rdg+ 2dgt) Diode: Ranges : 2V Resolution : 1mV Accuracy : ( 1.5% rdg+ 3dgt) Cpacitor: Ranges : 4nF / 40nF / 400nF / 4¼ F / 40¼ F 400¼ F / 4mF / 40mF Resolution : 1pF / 10pF / 100pF / 1nF / 10nF 100nF / 1¼ F / 10¼ F Accuracy : : 4nF : ± ( 2.5% rdg+ 4dgt) 40nF~ 40¼ F : ± ( 2.0% rdg+ 4dgt) 400¼ F~ 4mF : ± ( 2.5% rdg+ 4dgt) 40mF : ± ( 3.0% rdg+ 4dgt) GENERAL Conductor size : : Approx. 35mm Max. Operating principle : Dual slope integration. Over rage indication : " O.L" indicated. Low battery indication : : Response time : Approx. 1 second. Sample rate : Approx. 2 times per second. Temperature & humidity for guaranteed : 0oC to 50oC 80% Max. Storage temperature & humidity : -10oC to 60oC 80% Max. Battery life : Approx. 100 hours on continuous use.( Alkaline) Dimensions : 210( L) × 90( W) × 40( D) mm Weight ( battery Included) : Approx. 330g Power source : One type PP3, 6F22, 006P ( or equivalent) , 9V manganese. Safety standard : EN 61010-1 CAT III 600V EN 61326-1
Tampilkan Lebih Banyak