Back to Top

Hi, Guest!

TOTAL STATION NIKON DTM 352 SERIES

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0
Dilihat Sebanyak
:
20 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail TOTAL STATION NIKON DTM 352 SERIES

Model DTM-362, DTM-352, DTM-332 Telescope Tube Length 158mm/ 6.22 in. Magnification 33x ( 21x/ 41x with optional eyepieces) Effective diameter of objective 45mm/ 1.77 in. ( EDM: 50mm/ 1.97 in.) Field of view 1 20? Resolving power 2.5? Minimum focusing distance 1.3m/ 4.26 ft. Distance measurement Range with Nikon specified prisms Normal conditions ( Ordinary haze, visibility approx. 20km/ 12.5 miles) With reflector sheet ( 5 x 5cm) 5 to 100m ( 16.4 to 328 ft.) With mini prism 1, 000m/ 3, 280 ft. With single prism 2, 000m/ 6, 560 ft With triple prism 2, 600m/ 8, 530 ft. Good conditions ( No haze, visibility of over 40km/ 25 miles) With reflector sheet ( 5 x 5cm) 5 to 100m ( 16.4 to 328 ft.) With mini prism 1, 200m/ 3, 930 ft. With single prism 2, 300m/ 7.540 ft. With triple prism 3, 000m/ 9, 840 ft. Accuracy ( Prism/ Precise mode) ( 3+ 2ppm x D) mm ( 3+ 3ppm x D) mm ( ? 20 C to ? 10 C, + 40 C to + 50 C Measuring interval* 1 Precise mode 1.6 sec. ( initial 1.6 sec.) Normal mode 1.0 sec. ( initial 1.4 sec.) Least count Precise mode 1mm/ 0.002 ft. Normal mode 10mm/ 0.02 ft. Ambient temperature range* 2 ? 20 C to 50 C/ ? 4 F to + 122 F Atmospheric correction Temperature range ? 40 C to 60 C/ ? 40 F to + 140 F Barometric pressure 400 to 999mmHg/ 533 to 1, 332hPa/ 15.8 to 39.3 in.Hg Prism offset ? 999 to 999 Angle measurement Reading system Photoelectric detection by incremental encoder Horizontal angle Diametrical( DTM-362/ 352) , Single( DTM-332) Vertical angle Single Minimum increment ( Degree, Gon, MIL6400) Degree: 1/ 5/ 10? , Gon: 0.2/ 1/ 2mgon, MIL6400: 0.005/ 0.02/ 0, 05mil DIN 18723 accuracy ( horizontal and vertical) 5? / 1.5mgon ( 3? / 1.0mgon: DTM-362) Tilt sensor Type Dual-axis( DTM-362/ 352) , Single-axis( DTM-332) Method Liquid-electric detection Compensation range 3' Setting accuracy 1" Level vial Plate level vial 30" / 2mm Circular level vial 10' / 2mm Optical plummet Magnification 3x Focusing range 0.5m/ 1.6 ft. to  Display Graphic LCD ( 128 x 64 dot) Both sides( DTM-362/ 352) , Single side( DTM-332) Point memory 10, 000 records Dimensions ( W x D x H) 168 x 173 x 335mm/ 6.6 x 6.8 x 13.2 in. Weight ( approx.) Main unit ( with battery) 5.3kg/ 11.7 lbs.( DTM-362/ 352) , 5.2kg/ 11.5 lbs.( DTM-332) Battery 0.4kg/ 0.9 lbs Carrying case 2.4kg/ 5.3 lbs On-board Ni-MH battery BC-65 Operation time Continuous distance/ angle measurement Approx. 16 hours* 3 Distance/ angle measurement every 30 seconds Approx. 27 hours Angle measurement Approx. 30 hours Battery charger for BC-80/ 65 Approx. 2.0 hours for full recharge Quick charger Q-70C ( 12V DC cigarette lighter charger) Approx. 2.0 hours ( fully discharged BC-65 requires more than one charge) * 1 Measuring time may vary depending on measuring distance and conditions. * 2 A special version of the DTM-352 is available that allows operation at extremely low temperatures down to ? 30 C. * 3 At 25 C. Operation time may be shorter if battery is not new.
Tampilkan Lebih Banyak